5 Measurement of Durability Through Wear
|
|
Industrial Flooring: Why Apply Sealant to Impregnation, Coating or Screed?
by Dipl.-Chem. Dr. Peter Seidler
South African Conference on Polymers in Concrete, Berg-en-Dal, Kruger National Park Jun 20-23, 2000
5. Measurement of Durability Through Wear
The difference between just 2 mg and 150 mg of wear, i.e. 75 times greater, is critical. This means that a cheap product must be applied in a layer 75 times thicker than that of a good sealant in order to achieve the same durability as the best materials. The cheaper product thus involves much higher material and labour costs.
| Raw Material System |
min. |
max. |
| PUR 1-component |
2 |
15 |
| PUR 2-component |
10 |
35 |
| Aminoplastic alkyd |
40 |
60 |
| EP |
40 |
70 |
| Alkyd |
80 |
150 |
It will be objected that the technique used for measuring the wear is uncertain, and that there are many procedures. This point will be considered in another article.
|